TEST DATA:
All testing conducted by a recognized independent testing laboratory as approved by the American Architectural Manufacturer's Association and as CERTIFIED by AAMA in testing and production. Complete test report available upon request.
Structural Performance Class per AAMA/NWWDA 101/I.S.2-97 HS-HC50 / AW50
Water Test Pressure 9.00 PSF
Structural Test (Interior & Exterior) 75.0 PSF
Air Infiltration (@ 0.57 PSF) 0.04 cfm/ft²
(@ 1.57 PSF) 0.09 cfm/ft²
Operating Force (8'0" x 6'7" Window) 14 lbs.
Forced Entry Resistance Rating Level 10
Test results are based on independent laboratory testing of sizes prescribed by the corresponding AAMA test procedures. Actual field conditions, locations or variations in window size may introduce some deviation between these results and actual installed performance.
Customization and alternate details can be provided to fit your specific needs.
|